How to draw a CCTV layout plan, with camera coverage

By FortiDraw · 6 min read · 18 Nov 2026

A CCTV quote that says "eight cameras and a recorder" tells the customer almost nothing. Which doors are watched? Can the camera on the car park actually pick out a face, or just a shape? Where does the cable run? A CCTV layout plan answers those questions on one sheet, before anyone climbs a ladder.

Here is what a good CCTV layout drawing shows, why coverage matters most, the privacy side, and how to draw one on your own PDF plan.

What a CCTV layout plan shows

A camera layout is a floor or site plan with the system drawn over it. The useful ones show:

  • Camera positions, each with a reference (CAM-01, CAM-02) that matches the quote, the recorder channel and the label on site.
  • Camera type: wall or ceiling mounted, fixed or PTZ, wired or wireless.
  • What each camera sees: its direction, how wide its view is and how far it reaches, drawn as a cone.
  • Mounting height and anything the engineer needs to know about the fixing, usually as a note against the camera.
  • Cable routes back to the recorder (NVR or DVR) or the network switch, including where cameras are powered over the network cable (PoE) so the switch is chosen to suit.
  • The recorder, switch and monitor positions.
  • A legend that lists each symbol and how many there are.
  • A title block with the site, the drawing number, the revision, and who drew and checked it.

That one drawing becomes the scope the customer signs off, the job sheet the engineers install from, and the record whoever maintains the system will want years later.

Why coverage matters more than camera count

Placing cameras by eye often leaves two cameras on the same door and none on the back gate. Drawing each camera's view on the plan shows the blind spots straight away: the corner behind the bins, the stretch of corridor between two cones, the side passage nobody thought about.

Start with what each camera is for

Good CCTV design starts with an operational requirement: what each camera needs to achieve, not just where it fits. "See that someone came through the gate" and "identify who came through the gate" need very different cameras, lenses and distances.

The video surveillance standard IEC 62676-4 (published in Europe as EN 62676-4) puts this into numbers. Its 2014 edition describes four levels of detail, each tied to a minimum pixel density on the subject:

  • Detect: tell whether a person is there at all (about 25 pixels per metre).
  • Observe: see how many people there are and some details of them (about 63 px/m).
  • Recognise: tell whether this is someone you have seen before (about 125 px/m).
  • Identify: identify the individual (about 250 px/m).

Pixel density drops the further the subject is from the camera, so the same camera can identify a face near the door and only detect a figure at the far end of the yard. That is why a cone with distance bands tells you more than a cone alone.

A new edition, IEC 62676-4:2025, replaces the four levels with a longer set of categories, from Overview up to Scrutinize. If a specification names the standard, check which edition it means.

Privacy belongs on the drawing too

A cone that runs over the boundary fence is a privacy question, not just a drawing detail. The ICO's guidance for organisations expects cameras to be focused on the space that matters, with the view restricted where wider coverage isn't needed. It says a data protection impact assessment will be needed in most surveillance cases, done before the system goes in, and that signs should be clearly visible before people enter the camera's view.

For public authorities in England and Wales, the government's Surveillance Camera Code of Practice also applies, and other operators are encouraged to follow it voluntarily. Its principles include having a clear purpose, assessing the effect on privacy, and producing images good enough for that purpose.

Seeing every cone on the plan makes these conversations easy. You can show a customer exactly where the view crosses into a neighbour's garden or a staff rest area, and agree to move the camera, narrow it or mask it before the install. For homes, our guide to where to put home CCTV cameras covers the domestic rules.

How to draw a CCTV layout in FortiDraw

FortiDraw is floor-plan mark-up: you draw over the PDF plan you already have, on a computer, tablet or phone. Here is the CCTV job from start to finish.

1. Upload the plan and set the scale

Start a project from the PDF and choose CCTV as the system, so the camera symbols come first. Then set the scale: draw a line over a length you know, fit a room you have measured, or type the scale printed on the drawing. Until you do, coverage cones are drawn dashed and can't be sized in metres.

2. Place the cameras

Pick cameras from the CCTV trade in the Devices panel and click where each one goes. Each gets a tag, and you can mark a camera as new or existing, wired or wireless, so a survey of the old system stands apart from the new work. See Place devices.

3. Aim each camera and check its coverage

Drag the grip on the cone to turn the camera and set how far it reaches, and drag its edges to widen or narrow the view. In the Inspector, choose a lens preset or a custom angle and length, and FortiDraw shows the distances for Identify, Recognise, Observe and Detect as bands on the cone.

Then trace the walls as wall masks, and each cone stops where its camera can no longer see. Blind spots show up as plain floor. The cameras demo and the wall masks demo show both in the real editor. Coverage on the plan is a guide worked from the lens figures, so check positions on site. More in Camera coverage.

4. Draw the cable routes

Place the recorder and the network switch, then draw rails from each camera back to them. Rails stay attached when you move a device, can be curved or right-angled, and take a label such as the cable type. A rail from a camera to its recorder also links the two, so the recorder lists its cameras. See Connect devices with rails.

5. Add notes, the legend and a title block

Put mounting heights and fixing notes on each camera, with photos from site if you have them. Generate a legend that counts each kind of device, then put the page on a sheet with a title block: drawing number, revision, drawn by and checked by.

6. Export for the quote

Download the annotated PDF with the cones drawn as they look on screen, and a placements CSV with one row per device, including each camera's angle, range and direction, ready for the quote or the parts list. Downloads come with the paid plans; drawing and saving are free. See Export a PDF or CSV.

What FortiDraw doesn't do

FortiDraw draws what you decide. It doesn't pick cameras, check a design against a standard, or replace testing the real camera and lens on site. It makes your decisions clear, so the customer, the engineers and the maintainer see the same plan.

Draw your camera layout free

Upload your floor plan, place the cameras, aim them and see the coverage and blind spots before a single bracket goes up.

If you fit cameras for a living, see FortiDraw for CCTV engineers for a whole job from survey to quote.

Mark up a CCTV plan free at FortiDraw. For a whole job with fire, access control and data on the same drawing, see security floor plans on one drawing.


General information, checked in November 2026, not advice for a particular site. See the ICO's video surveillance guidance (under review after the Data (Use and Access) Act) and the Surveillance Camera Code of Practice for the current position.

More on CCTV

Fire alarm grades explained: A, C, D1, D2, F1 and F2Fire alarm grades describe the kind of system in a home. The six grades in BS 5839-6:2019+A1:2020, how a grade differs from a category such as LD2, and which grade is recommended where.Fire safety · 5 min · 19 Nov 2026Fire alarm system categories explained: M, L1–L5, P1, P2 and LD1–LD3Every UK fire alarm system category on one page: M, L1 to L5, P1 and P2 from BS 5839-1, and LD1 to LD3 from BS 5839-6 for homes, each in a sentence or two, with a diagram and links to the detailed guides.Fire safety · 4 min · 19 Nov 2026L1 fire alarm system requirements: what whole-building cover meansAn L1 fire alarm system has automatic detection throughout the building. The L1 definition, the low-risk areas BS 5839-1 lets you leave out, what changed in 2025, and when L1 is specified.Fire safety · 3 min · 19 Nov 2026